Mighty-mule FM500 Blue Board Manuale Utente

Navigare online o scaricare Manuale Utente per Sicurezza Mighty-mule FM500 Blue Board. Mighty Mule FM500 Blue Board User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 43
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
Installation Manual
1. KEEP CLEAR! Gate may move at any time.
2. Do not allow children to operate gate or
play in gate area.
3. This gate is for vehicles only. Pedestrians
must use a separate entrance.
Moving Gate Can Cause
Injury Or Death
WARNING
!
WARNING
!
MOVING GATE
Can Cause Injury or Death
500
®
E-Z GATE OPENER
1-800-543-GATE (4283) • www.mightymule.com
UL325 SERIES
500
®
E-Z GATE OPENER
SINGLE GATE SYSTEM
5 Easy Installation Steps
1. Watch the Installation DVD and Read the Safety Information,
Technical Specifications, and the Before You Begin sections in
the manual.
2. Install the Gate Opener and Control Box.
3. Power the system using the AC Transformer or optional Solar
Panel Charger Kit.
4. Programming and customizing the system to your individual
settings.
5. Adding additional safety devices and access controls.
L
I
S
T
E
D
USC
REV-11/17/08
Printed in China for GTO, Inc.
Vedere la pagina 0
1 2 3 4 5 6 ... 42 43

Sommario

Pagina 1 - Installation Manual

Installation Manual1. KEEP CLEAR! Gate may move at any time.2. Do not allow children to operate gate or play in gate area.3. This gate is for vehicles

Pagina 2 - Warning!

Important Safety Information7Warning signs alert people of automatic gate operation and are required when installing the Mighty Mule® 500 Automatic Ga

Pagina 3 - Table of Contents

Important Safety Information8!LISTEDUS500UL325 SERIES®®E-Z GATE OPENERCProduct identification and manual operation instruction label (1) installed on

Pagina 4 - Please Read This First!

Technical Specifications9Mighty Mule® 500 E-Z Gate OpenerDRIVE•Lowfrictionscrewdrive(linearactuator)ratedfor-5ºFto+160ºF(-20ºCto+71º

Pagina 5

Check Direction of Gate SwingBefore You BeginYour Property Your PropertyIMPORTANT: Check for Proper Gate InstallationEABCDFCheck Existing Gate Size an

Pagina 6

Column Installation InformationBefore You Begin3/8” x 1-1/4” Clevis Pin (2)RB50012 Volt / 7.0 Amp MountInstallation Overview for the...3/8” x 8”

Pagina 7

x23/8” Bit 5/16” BitDrillPliersLevelClampAdjustableWrenchPenCenterPunchHammerTapeMeasureSmallFlat HeadPhilips HeadScrewdriverFlat HeadScrewdriverWireS

Pagina 8

13Mounting Pull-to-Open Opener to GateGate Opener InstallationISVHIRY1XXFMMQBQ2Attach opener to gate bracket and secure with required hardware.Assemb

Pagina 9

14Mounting Pull-to-Open Opener to GateGate Opener InstallationOPEN gate and re-attach opener with clevis pin. Check for level. Clamp securely.UOZN7Sec

Pagina 10 - Important Safety Information

15Mounting Pull-to-Open Opener to GateGate Opener Installation12YSTR112213Attach and secure opener assembly to brackets.Attach gate bracket assembly t

Pagina 11

16Assemble post bracket parts. NOTE: A Push-to-Open Bracket FM148 is required for this type of installation (not included).IIRVSYPTOBracketFM14811” 1X

Pagina 12 - Technical Specifications

Warning!The Mighty Mule® Gate Opener is intended for use with vehicular swing gates. The opener can be used in Class I, Class II, Class III and Class

Pagina 13 - Before You Begin

CLOSE gate and re-attach opener with clevis pin. Check for level. Clamp securely.16NUOZ7Secure post pivot bracket to post bracket when clearance is OK

Pagina 14

18Mounting Push-to-Open Opener to GatePush-to-Open InstallationYour Property12YSTR13Attach and secure opener assembly to brackets.Attach gate bracket

Pagina 15

19Control Box InstallationRemove control box cover.15A1Locate control box mounting area. IMPORTANT: Be sure to mount box at least 3ft from AC power an

Pagina 16 - Gate Opener Installation

20RECEIVERLEARNSLV LIMI T S4ALMCHARGINGPWR I NGTO RCVR.WHTBLUBRNORGREDBLKGRNWHTBLUBRNORGREDBLKGRNCOMGRNBLKREDCYCLESAFETYEXITSHADOWOPENEDGECOMAU

Pagina 17

2111C31121215FUSEBATT+BATT-RECEIVERGTO RCVR.GTOLOCKAUXRLYPOWERINPUTSCONTROLINPUTSMASTER CABL ESLAVE CABLECONTROL INPUTSON STATUSLEARN RMTRECEIVE

Pagina 18

22FCC RegulationThis device complies with FCC rules Part 15. Operation is subject to the following conditions:1. This device may not cause harmful int

Pagina 19

Solar Panel Installation23Winter Ratings Zone 1 Zone 2 Zone 312 v single gate (10 watts) solar charger8 16 2612 v single gate ( 5 wa

Pagina 20 - Push-to-Open Installation

24GRN WHT BLUE BRNWHTBLUBRNORGGRNSLAVE CABLE1 2 3 4 5GTO 18VOLTTRANSFORMEROR SOLARPOWERINPUTSLOCKPWRAUXRLYCONTROLOUTPUTSCorrectWrong Wrong515FUSEBAT

Pagina 21

Control Box Settings15DIP#1ON**___Soft start enabled (factory preset).OFF __Soft start disabled.DIP#2ON**___Buzzer warning enabled (factory preset)

Pagina 22 - Control Box Installation

Setting Pull-to-Open (Closed) Gate Limit (for push-to-open go to pg. 16)15ON13212Control Box Settings151 2 3 4ON LEARNMAST LIMIT LEARNSLV LI

Pagina 23

Table of Contents PLEASE READ THIS FIRST _______________________________________________________ 1IMPORTANT SAFETY INFORMATION _____________________

Pagina 24

27With gate in CLOSED position, turn control box power switch to ON.Press button on opener remote; gate should start opening. Press but-ton on opener

Pagina 25

Turn the “STALL FORCE” arrow in the center of the potentiom-eter with small flat head screwdriver. Adjust the sensitivity from the MINIMUM position up

Pagina 26 - Solar Panel Installation

29Control Box SettingsFCC RegulationThis device complies with FCC rules Part 15. Operation is subject to the following conditions:1. This device may n

Pagina 27 - Multiple Panel Installations

30Connecting Additional DevicesAlthough GTO strongly recommends the use of additional safety devices, we do not endorse any specific brand names. Only

Pagina 28 - Control Box Settings

311 COM: Circuit common (reference for all logic input) •Two(2)terminalstoprovideextracommonconnectionpoint.2 CYCLE: (Typically for use

Pagina 29

Connecting Accessories32Connecting Additional DevicesGTO Photo BeamsGTO Loop DetectorMighty MulePush Button ControlAccording toApplicationAccording to

Pagina 30 - Control Box Settings

Maintenance & Troubleshooting33•Onallgatesweighing250lb.ormore,routinelygrease the ball bearing hinges at least 4 times a year; more fr

Pagina 31

34Troubleshooting Guide If your gate opener does not function properly after it is installed, use this guide before calling the GTO Service Department

Pagina 32

35Visual FeedbackSymptomDiagnosis Check:Status (clear)1 blinkCycle Terminal ShortedDisconnect the push button, keypad, intercom keypad, or any otherac

Pagina 33 - Connecting Additional Devices

Repair Service1. First use the procedures found in the Maintenance & Troubleshooting Guide (see page 33). 2. If you are unable to solve the pr

Pagina 34

1Please Read This First!Thank you for purchasing a Mighty Mule® E-Z Gate Opener—GTO's "do-it-yourself" automatic gate opener! When corr

Pagina 35

37For Your RecordsPlease record the product serial number (located on the right hand side of the control box), and the date and place of purchase in t

Pagina 36

38Accessories are Available From Your Retail Store®E-Z GATE OPENERSACCESSORIESAUTO MATIC GATE LO CKSolar Panel (FM121) The Solar Panel is a 5 watt s

Pagina 37 - Audible Feedback

39If you have a question about any special order item, just call 1-800-543-GATE!Accessories are Available From Your Retail Store (con't)The conte

Pagina 38 - Visual Feedback

For sales call toll free:1-800-543-GATE (4283)The GTO, Inc. Sales Department is open Monday – Friday 8:00 A.M. – 5:00 P.M. (Eastern Time)For technical

Pagina 39 - Telephone (850) 575-4144

Important Safety InformationClevis PinHairpin ClipGate BracketFront MountBushingBecause automatic gate openers produce high levels of force, consumer

Pagina 40 - Conversion Chart

Important Safety Information3 1. READ AND FOLLOW ALL INSTRUCTIONS. Failure to meet the requirements set forth in the instruction manual could caus

Pagina 41 - ACCESSORIES

Important Safety InformationMoving GateAreaDriveway10'10'10'10'NEVER installany control devicewithin gray area4II. During Installa

Pagina 42

Important Safety Information5III. After Installation 1. Attach the warning signs (included) to each side of the gate to alert the public of automati

Pagina 43 - E-Z GATE OPENERS

Important Safety Information6As specified by Gate Operator Safety Standard, UL 325 (30A.1.1), automatic gate operators shall have an inherent entrapmen

Commenti su questo manuale